Fan and Pump Energy Savings by Speed Control
Keywords: Energy Saving Motor for Fans and Pumps / Variable Speed Pump Motor / Affinity Law Energy Saving Motor
The affinity laws, stated plainly
For a centrifugal fan or pump, three relationships govern everything:
表格
Variable
Relationship
Meaning
Flow
Q ∝ n
Half the speed, half the flow
Head / pressure
H ∝ n²
Half the speed, a quarter of the head
Power
P ∝ n³
Half the speed, one eighth of the power
The third line is the entire economic case for variable speed. It is also the line that gets misquoted, because it holds only for centrifugal loads, and only when the system curve allows the operating point to move.
Why throttling wastes what speed control saves
Traditional flow control uses a valve or damper: the motor runs at full speed, and the restriction absorbs the excess pressure.
表格
Control method
Motor speed
Power at 80% flow (55 kW unit)
Throttle / damper
100%
≈ 50 kW — the restriction burns the difference…