The "standard configuration" of professional maintenance vehicles
The nominal inductance between pins 1 and 5 is 25mH±15%, measured under a standard test condition of 1kHz and 1V. The product uses vacuum impregnation and meets Class B insulation requirements. The winding-to-core insulation is tested at AC1500V, 5mA for 3 seconds.
1. Inductance performance
The inductance is measured between pins 1 and 5 and specified as 25mH±15%. The standard test condition is 1kHz and 1V, using a 3259 comprehensive tester or an equivalent instrument.
2. Dielectric strength
The winding-to-core insulation is tested at AC1500V with a test current of 5mA for 3 seconds.
3. Vacuum impregnation
The product uses vacuum impregnation to support coil fixation and insulation-structure stability. Final process acceptance shall follow the mutually confirmed product specification.
4. Insulation class
The product is specified as Class B insulation. For equipment with specific temperature, insulation-system or sa…